ASTM E8 E8M PDF

AHM E8/E8M – 13a. G–Gauge length. Dimensions, mm [in.] For Test Specimens with Gauge Length Four times the Diameter (E8]. Standard. Small-Size. Buy ASTM E 8/E8M: A TEST METHODS FOR TENSION TESTING OF METALLIC MATERIALS from SAI Global. Originally contact ASTM Customer Service at [email protected] For Annual Book of ASTM approved in Last previous edition approved as E8/ E8M.

Author: Shalrajas Dagul
Country: Armenia
Language: English (Spanish)
Genre: Automotive
Published (Last): 8 August 2013
Pages: 470
PDF File Size: 6.81 Mb
ePub File Size: 7.28 Mb
ISBN: 326-2-81097-936-1
Downloads: 89264
Price: Free* [*Free Regsitration Required]
Uploader: Tygolkree

For proper gripping, it is desirable that the entire length of the serrated face of each wedge be in contact with the specimen. For best results, the wedges should be supported over their entire lengths by the heads of the testing machine. Astm c astm normas fibra de vidrio. C39M – 16 – Compressive Strength of Cylindrical The distance between spherical bearings should be as great as feasible.

NOTE 1—The effect of this eccentric force application may be illustrated by calculating the bending moment and stress thus added. Such interpretation is usually applicable to values for reduction of area reported in the literature when no further qualification is given. Proper alignment of wedge grips and liners is illustrated in Fig. These wedge grips generally furnish a satisfactory means of gripping long specimens of ductile metal.

NOTE 3—Punching or blanking of the reduced section may produce significant cold work or shear burrs, or both, along the edges which should be removed by machining.

E8M Tensiont testing of metallic materials Juliano row Enviado por: For measuring elongation at fracture with an appropriate extensometer, the gauge length of the extensometer shall be equal to the nominal gauge length required for the specimen being tested.

  HANDBOOK OF PERFORMABILITY ENGINEERING PDF

ASTM E8 / E8M – 13 Standard Test Methods for Tension Testing of Metallic Materials

The values stated in asym system are not exact equivalents; therefore each system must be used independently of the other. This requires that liners of several thicknesses be available to cover the range of specimen thickness.

When liners are used behind the wedges, they must be of the same thickness w8 their faces must be flat and parallel. Parte 1 de 8 Designation: If, however, for any reason, one grip of a pair advances farther than the other as the grips tighten, an undesirable bending stress may be introduced. A superscript epsilon indicates an editorial change since the last revision or reapproval. The test methods have been used extensively in the trade for this purpose.

Both of these gripping devices should be attached to the heads of the testing machine through properly lubricated sphericalseated bearings. Originally approved in To 8e axial tensile stress within the gauge length, the axis of the test specimen should coincide with the center line of the heads of the testing machine.

For this reason, a small taper is permitted in the reduced section of each of the specimens described in the following sections. Adtm Materials—A schematic diagram of a gripping device for threaded-end specimens is shown in Fig.

It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  FROGS INTO PRINCES NLP PDF

ASTM E8.E8M -15-Tensiont testing of metallic materials

Astm a Astm a The gauge length is the most significant difference between E8 and E88 test specimens. This information may be useful in comparisons of materials, alloy development, quality control, and design under certain circumstances.

The forces used in determining tensile strength and yield strength shall be within the verified force application range of the testing machine as defined in Practices E4.

This error increases to 2.

For a standard No further reproductions authorized. Combining values from the two systems may result in non-conformance with the standard. A number in parentheses indicates e year of last reapproval. Any departure from this requirement may introduce bending stresses that are not included in the usual stress computation force divided by cross-sectional area. Extensometers shall be used and verified to include the strains corresponding to the yield strength and elongation at e8k if determined.

Current edition approved May 1, For short specimens and for specimens of many materials e is generally necessary to use machined test specimens and to use a special means of gripping to ensure that the specimens, when under load, shall be as nearly as possible in uniformly distributed w8 axial tension see 5. It is important, therefore, that care be exercised in the preparation of specimens, particularly in the machining, to maximize precision and minimize bias in test results.